CSE Cable
CSE Cables - Supplier of industrial cable
BS5308 Cable
BS5308 Part 1
Type 1 Unarmoured
- Collectively Screened
- Individually & collectively screened
Type 2 Armoured
- Collectively Screened
- Individually and Collectively Screened
- Part 1 Technical Data
- Part 1 Unscreened Pairs
BS5308 Part 2
Type 1 Unarmoured
- Multipair Collectively Screened
- Multipair Collectively screened
- Multipair, individually and collectively screened
Type 2 Armoured
- Multipair collectively screened
- Multipair collectively screened
- Multipair individually and collectively screened
- Part 2 Technical Data
- Part 2 Unscreened Pairs
BS5308 LSF
BS5308-1-1 0.75 1P LSF
BS5308-1-1 0.75 1Q LSF-2

BS5308 Cables Part 2 Technical Data

Maximum working voltage: 300/500V r.m.s.

Test Voltage: 1000V r.m.s. between conductors and between conductors and screen/armour

Maximum conductor operating temp: + 65°C

Minimum ambient temp: -40°C after installation and only when cable is in a fixed position

Maximum conductor d.c. resistance: W/km at 20°C

Conductor size Multi-core Multipair
16/0.20mm (0.5mm2) 39.0 39.7
24/0.20mm (0.5mm2) 26.0 26.5
7/0.53mm (1.5mm2) 12.1 12.3

Minimum insulation resistance: Individual conductors - 25MW.Km at 20°C. Between individual screens - 1 MW.Km at 20°C

Maximum L/R ratio:

Conductor size µH/W
0.5mm2 25
1.0mm2 25
1.5mm2 40

Maximum capacitance unbalance: 450pF/metre 1 kHz

Maximum mutual capacitance at 1 kHz: Pair of adjacent cores - 250 pF/m at 1kHz.

Spread of flame: Type 1 complies with BSEN 50265-2-1, HD 405-1 IEC 332-1 Type 2 complies as Type 1 and additionally with IEC 332-3.

Minimum bending radius: Type 1 - 5 x overall diameter. Type 2 - 6 x overall diameter.