Nexans NXS Cable
Prysmian LSX Cable

Prysmian Afumex LSX CablePrysmian Afumex LSX Cable

 

Conductor : Plain annealed copper stranded (class 2)conductor. The CPD for 1.0mm² and 1.5mm² is a solid (class 1) conductor

Insulation : 90°C cross-linked XLPE insulation

Core identification : o o brown-blue; o o o brown-black-grey; o o o o blue-brown-black-grey

Sheath : Robust thermoplastic Afumex sheath

Colour : white.

Bending Radius : Circular Conductor r=6D

Fire Performance : BSEN60332-1-2; BSEN50266-2-4

Flexibility : Rigid

Halogen Free : BSEN50267-2-1, BSEN50267-2-3

Mechanical Impact : Medium

Low Smoke Emissions : BSEN50268-2

Temperature Range : -25 to +90oC

Nominal cross sectional area 
Approx. overall diameter 
Approx. cable weight 
Max conductor resistance at 20°C 
Current rating DC or single phase AC 
Current rating DC or single phase AC clipped 
Current rating DC or single phase AC perforated tray 
Current rating three phase AC clipped direct 
Current rating three phase AC perforated tray 
Volt drop DC or single phase AC 
Volt drop three phase AC 
mm² 
mm 
kg/km 
ohms/km 
enclosed Amps 
direct Amps 
Amps 
Amps 
Amps 
mV/A/m 
mV/A/m 
Two Core
1.0
8.9
88
18.1
17
19
21
--
-
46
-
1.5
9.4
104
12.1
22
24
26
-
-
31
-
2.5
10.4
138
7.41
30
33
36
-
-
19
-
4.0
11.6
190
4.61
40
45
49
-
-
12
-
6.0
12.6
254
3.08
51
58
63
-
-
7.9
-
Three Core 
1
9.4
105
18.1
17
19
21
17
18
46
40
1.5
10.1
128
12.1
22
24
26
22
23
31
27
2.5
11.1
172
7.41
30
33
36
30
32
19
16
Four Core 
1
10.1
122
18.1
17
19
21
17
18
46
40
1.5
11.1
153
12.1
22
24
26
22
23
31
27
2.5
11.6
204
7.41
30
33
36
30
32
19
16
4
13.4
288
4.61
40
45
49
40
42
12
10
Seven Core† 
1.5
11.5
220
12.1
22* 
24* 
26
-
-
31
-

†Details of other multicore designs are available upon request.
*The tabulated rating is as a two core cable and may be used where the number of cores carrying current does not exceed the square root of the total number of cores.
Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations.
The tabulated ratings are based upon a 30°C ambient temperature and 90°C operating temperature. For other ambient temperatures or where cables are grouped together, the appropriate rating
factors should be applied.

Temperature Rating Factors

Ambient Temperature °C
25
30
35
40
45
50
55
60
Rating Factor
1.02
1.00
0.96
0.91
0.87
0.82
0.76
0.71


Correction factors for Groupings (Free Air Touching)

Number of Circuits
2
3
4
5
6
7
8
9
Rating Factor
0.86
0.82
0.80
0.79
0.78
0.78
0.78
0.77

 

CSE Cables : Unit 16, Wessex Road, Bourne End, Bucks, SL8 5DT