CSE Cable
CSE Cables - Supplier of industrial cable
Reeling Cables
H07VVH6-F
VCVH6-F
Rheyflat-N NGFLGOEU-J
Rheyflat-N (N)GFLCGOEU-J
LSHF
RHEYFESTOON (N)3GRD5G
RHEYFESTOON (C) (N)3GRDGC5G
RHEYCORD-OFE M
BUFLEX DGR
RHEYCORD NSHTOEU-J
RHEYCORD (RTS) (N)SHTOEU-J
RHEYCORD-PUR R
BUFLEX SC
BUFLEX SEM
BUFLEX SEM OFE
RHEYFIRM (RTS) (N)TSCGEWTOEUS
RHEYFIRM (RTS) (N)TSCGEWTOEUS OFE
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
RHEYCORD-OFE R
RHEYCORD-OFE SR
Special Cables
BOITALYON R
RHEYFLEX-PN
RHEYCORD(BS) YSLZ3SOE-J
RHEYFIRM(SI) NTMCGCWOEUS
Further Information
Cable Conductors
Cable Compounds
Cable Strength Member
Anti Torsion Braid
Bending Radius
Letter Codes
Units of Measurement
Voltage Definition
Current Carrying
BUS System
Optical Fibre
Mechanical Testing for Handling Cables
 

PVC Flat CableH07VVH6-F PVC Flat Cable

Applications

Power and control flat cables can be used on festoon systems on
handling equipments e.g. overhead cranes. Specially designed for indoor and outdoor applications.

Design

1. Conductor : Flexible plain copper class 5
IEC 60228
2. Insulation : PVC, threads are placed in each group of cores to strip the outer sheath.
3. Outer sheath : PVC Colour: black

H07VVH6-FMarking

H07VVH6-F or 07VVH6-F
Number of cores - Cross-section
NEXANS year - week

Cores Identification

in accordance with HD 308 S2
4 cores: black - grey - green/yellow - brown
5 cores: black - grey - green/yellow - brown - blue
>5 cores: black with white printed numbers + green/yellow

Standards

HD 359 S2
IEC 60227 part 6

Mechanical Properties

Tensile stress of the conductor static 15 N/mm2
  dynamic 30 N/mm2
Tests Bending test
Travelling Festoon speed up to 120 m/min
   

Chemical Properties

Oil, acid and alcaline resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.

Electrical and Thermal properties

Nominal voltage Uo/U 450/750 V
Maximum operating voltage in AC systems Um 750 V
Test voltage 2.5 kV - 50 Hz in AC

Max. temperature at the conductor :
- in service
- in short circuit


+ 70 °C
+ 150 °C
Max. surface temperature :
- fixed installation
- mobile operation

- 35 °C up to + 60 °C
- 25 °C up to + 60 °C
   
Number of cores and nominal
cross-section
(mm2)
Outer dimensions
approx.
(mm)
Weight
approx.
(kg/km)
POWER
4 G 4* 
21 x 6.5 
300
4 G 6* 
23 x 7 
390
4 G 10* 
29 x 9 
620
4 G 16* 
37 x 11 
990
4 G 25* 
46 x 13.5 
1,550
4 G 35* 
51 x 14.8 
2,030
4 G 50* 
56 x 16.5 
2,650
4 G 70* 
63 x 18 
3,650
4 G 95* 
73 x 20.5 
4,550
5 G 4* 
25 x 6.5 
380
5 G 6* 
28 x 7 
480
5 G 10* 
35 x 9 
780
5 G 16* 
43 x 11 
1,200
7 G 4* 
37 x 6.5 
550
7 G 6* 
41 x 7 
700
CONTROL
4 G 1.5* 
15 x 5 
150
4 G 2.5* 
18.5 x 6 
210
5 G 1.5* 
18 x 5 
180
5 G 2.5* 
22 x 6 
260
7 G 1.5* 
26 x 5 
260
7 G 2.5* 
32 x 6 
380
8 G 1.5* 
29 x 5 
300
8 G 2.5* 
35 x 6 
405
10 G 1.5* 
35 x 5 
360
12 G 1.5* 
40.5 x 5 
420
12 G 2.5* 
50.5 x 6 
620
12 G 4 
57 x 6.5 
880
14 G 1.5* 
48 x 5 
490
16 G 1.5* 
54 x 5 
560
18 G 1.5* 
58 x 5 
620

Options

Cables without earth core (green/yellow) on request
Remark: <HAR> CENELEC types are only up to 16 mm2

CSE Cables : Unit 16, Wessex Road, Bourne End, Bucks, SL8 5DT
Tel : 01628 850024; Fax : 01628 648068; Email :
CSE Cable