RHEYCORD® NSHTOEU-JRubber reeling cable for control and power supplies. For applications with high mechanical stress, especially for simultaneous tensile and torsional stress. Suitable for motor-driven reels, spring-operated reels and hoisting systems.
1. Conductor
Flexible, tinned copper, “FSC”
better than IEC 60228 class 5
2. Insulation
EPR, rubber compound
3GI3 refer to
DIN VDE 0207 part 20
3. Inner sheath
Rubber compound
5GM3 refer to
DIN VDE 0207 part 21
4. Outer sheath
Rubber compound
5GM3 refer to
DIN VDE 0207 part 21,
low abrasion and notch
resistant, with anti-torsion
braid integrated in the sheath
Colour: black
RHEYCORD NSHTOEU-J Number of cores - cross-section 0.6/1 kV - NEXANS <VDE> year
DIN VDE 0293 part 308/
HD 308 S2
4 cores:
green/yellow - brown -
black - grey
5 cores:
green/yellow - blue - brown -
black - grey
≥ 5 cores:
black with white printed numbers -
green/yellow (in the outer layer)
DIN VDE 0250 part 814
| Tensile stress of the conductor | static | 15 N/mm2 |
| dynamic | 30 N/mm2 | |
| Bending radii | according to DIN VDE 298, | |
| Tests | alternating/reversed and roller bending test, | |
| torsional resistance test | ||
| Reeling speed | up to 120 m/min |
Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.
| Nominal voltage | Uo/U | 0.6/1 kV |
| Maximum operating voltage in AC systems | Um | 1.2 kV |
| Maximum operating voltage in DC systems | Vm | 1.8 kV |
| Test voltage: | ||
| - Power | 2.5 kV in AC | |
| - Control | 2.0 kV in AC | |
| Current rating (A) | according to DIN VDE 0298 part 4, | |
| see electrical characteristics page 3.2 B | ||
| Max. temperature at the conductor : | ||
| - in service | + 90 °C | |
| - under short-circuit conditions | + 200 °C | |
| Max. surface temperature : | ||
| - fixed installation | - 45 °C up to + 80 °C | |
| - mobile operation | - 35 °C up to + 80 °C | |
Number of cores and nominal cross-section |
Outer diameter |
Weight approx. |
||
(mm2) |
Min. (mm) |
Max. (mm) |
(kg/km) |
|
| CONTROL | 3 x 1.5* |
12 |
14 |
210 |
4 x 1.5* |
13 |
15 |
250 |
|
5 x 1.5 * |
14 |
16 |
285 |
|
7 x 1.5 * |
18 |
20 |
405 |
|
12 x 1.5* |
20 |
22 |
570 |
|
18 x 1.5* |
24 |
26 |
790 |
|
24 x 1.5* |
27 |
29 |
1,000 |
|
30 x 1.5* |
30 |
32 |
1,215 |
|
42 x 1.5* |
36 |
39 |
1,700 |
|
4 x 2.5* |
15 |
17 |
320 |
|
5 x 2.5* |
17 |
19 |
430 |
|
7 x 2.5* |
20 |
22 |
525 |
|
12 x 2.5* |
23 |
25 |
750 |
|
18 x 2.5 |
27 |
29 |
1,060 |
|
24 x 2.5* |
32 |
34 |
1,455 |
|
30 x 2.5 |
33 |
35 |
1,575 |
|
50 x 2.5* |
45 |
47 |
2,855 |
|
| POWER | 4 x 4* |
18 |
20 |
465 |
4 x 6* |
20 |
22 |
585 |
|
4 x 10* |
24 |
26 |
900 |
|
4 x 16* |
27 |
29 |
1,235 |
|
4 x 25* |
33 |
35 |
1,830 |
|
4 x 35* |
36 |
38 |
2,360 |
|
4 x 50* |
42 |
44 |
3,210 |
|
4 x 70* |
47 |
49 |
4,345 |
|
4 x 95* |
54 |
56 |
5,565 |
|
4 x 120* |
61 |
63 |
6,895 |
|
5 x 4* |
19 |
21 |
550 |
|
5 x 6* |
22 |
24 |
730 |
|
| BUS | 6 x (2 x 1.5) C* |
28 |
31 |
980 |
| COMPOSITE | 19 x 2.5 + 5 x 1.5 (CE)* |
31 |
33 |
1,450 |
25 x 2.5 + 5 x 1.5 (CE)* |
35 |
37 |
1,850 |
|
• Further numbers of cores and cross-section upon request
• Integrated BUS system cable
• Integrated Optical Fiber Elements
• Special cold resistant compound