CSE Cable
CSE Cables - Supplier of industrial cable
Reeling Cables
H07VVH6-F
VCVH6-F
Rheyflat-N NGFLGOEU-J
Rheyflat-N (N)GFLCGOEU-J
LSHF
RHEYFESTOON (N)3GRD5G
RHEYFESTOON (C) (N)3GRDGC5G
RHEYCORD-OFE M
BUFLEX DGR
RHEYCORD NSHTOEU-J
RHEYCORD (RTS) (N)SHTOEU-J
RHEYCORD-PUR R
BUFLEX SC
BUFLEX SEM
BUFLEX SEM OFE
RHEYFIRM (RTS) (N)TSCGEWTOEUS
RHEYFIRM (RTS) (N)TSCGEWTOEUS OFE
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
RHEYCORD-OFE R
RHEYCORD-OFE SR
Special Cables
BOITALYON R
RHEYFLEX-PN
RHEYCORD(BS) YSLZ3SOE-J
RHEYFIRM(SI) NTMCGCWOEUS
Further Information
Cable Conductors
Cable Compounds
Cable Strength Member
Anti Torsion Braid
Bending Radius
Letter Codes
Units of Measurement
Voltage Definition
Current Carrying
BUS System
Optical Fibre
Mechanical Testing for Handling Cables
 

NSHTOEU-JRHEYCORD® NSHTOEU-J

Reeling Cables 0.6/1 (1.2) kV

 

Applications

Rubber reeling cable for control and power supplies. For applications with high mechanical stress, especially for simultaneous tensile and torsional stress. Suitable for motor-driven reels, spring-operated reels and hoisting systems.

Design

1. Conductor
Flexible, tinned copper, “FSC” better than IEC 60228 class 5

2. Insulation
DesignEPR, rubber compound 3GI3 refer to DIN VDE 0207 part 20

3. Inner sheath
Rubber compound 5GM3 refer to DIN VDE 0207 part 21

4. Outer sheath
Rubber compound 5GM3 refer to DIN VDE 0207 part 21, low abrasion and notch resistant, with anti-torsion braid integrated in the sheath
Colour: black

Marking

RHEYCORD NSHTOEU-J Number of cores - cross-section 0.6/1 kV - NEXANS <VDE> year

Core Identification

DIN VDE 0293 part 308/ HD 308 S2
4 cores: green/yellow - brown - black - grey
5 cores: green/yellow - blue - brown - black - grey
≥ 5 cores: black with white printed numbers - green/yellow (in the outer layer)

Standards

DIN VDE 0250 part 814

Mechanical properties

Tensile stress of the conductor  static  15 N/mm2 
dynamic  30 N/mm2
Bending radii  according to DIN VDE 298,   
Tests  alternating/reversed and roller bending test,   
torsional resistance test   
Reeling speed  up to 120 m/min   


Chemical properties

Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.

Electrical and Thermal properties

Nominal voltage  Uo/U  0.6/1 kV 
Maximum operating voltage in AC systems  Um  1.2 kV 
Maximum operating voltage in DC systems  Vm  1.8 kV 
Test voltage:   
- Power 2.5 kV in AC   
- Control 2.0 kV in AC   
Current rating (A)  according to DIN VDE 0298 part 4,   
see electrical characteristics page 3.2 B   
Max. temperature at the conductor :   
- in service + 90 °C   
- under short-circuit conditions + 200 °C   
Max. surface temperature :   
- fixed installation - 45 °C up to + 80 °C   
- mobile operation - 35 °C up to + 80 °C   

 

 

Number of cores and
nominal cross-section
Outer diameter
Weight
approx.
(mm2)
Min.
(mm)
Max.
(mm)
(kg/km)
CONTROL
3 x 1.5* 
12
14
210
4 x 1.5* 
13
15
250
5 x 1.5 * 
14
16
285
7 x 1.5 * 
18
20
405
12 x 1.5* 
20
22
570
18 x 1.5* 
24
26
790
24 x 1.5* 
27
29
1,000
30 x 1.5* 
30
32
1,215
42 x 1.5* 
36
39
1,700
4 x 2.5* 
15
17
320
5 x 2.5* 
17
19
430
7 x 2.5* 
20
22
525
12 x 2.5* 
23
25
750
18 x 2.5 
27
29
1,060
24 x 2.5* 
32
34
1,455
30 x 2.5 
33
35
1,575
50 x 2.5* 
45
47
2,855
POWER
4 x 4* 
18
20
465
4 x 6* 
20
22
585
4 x 10* 
24
26
900
4 x 16* 
27
29
1,235
4 x 25* 
33
35
1,830
4 x 35* 
36
38
2,360
4 x 50* 
42
44
3,210
4 x 70* 
47
49
4,345
4 x 95* 
54
56
5,565
4 x 120* 
61
63
6,895
5 x 4* 
19
21
550
5 x 6* 
22
24
730
BUS
6 x (2 x 1.5) C* 
28
31
980
COMPOSITE
19 x 2.5 + 5 x 1.5 (CE)* 
31
33
1,450
25 x 2.5 + 5 x 1.5 (CE)* 
35
37
1,850


Options

• Further numbers of cores and cross-section upon request
• Integrated BUS system cable
• Integrated Optical Fiber Elements
• Special cold resistant compound

 

CSE Cables : Unit 16, Wessex Road, Bourne End, Bucks, SL8 5DT
Tel : 01628 850024; Fax : 01628 648068; Email :
CSE Cable