RHEYCORD® NSHTOEU-J
Reeling Cables 0.6/1 (1.2) kV
Applications
Rubber reeling cable for control
and power supplies.
For applications with high
mechanical stress, especially
for simultaneous tensile and
torsional stress.
Suitable for motor-driven reels,
spring-operated reels and
hoisting systems.
Design
1. Conductor
Flexible, tinned copper, “FSC”
better than IEC 60228 class 5
2. Insulation
EPR, rubber compound
3GI3 refer to
DIN VDE 0207 part 20
3. Inner sheath
Rubber compound
5GM3 refer to
DIN VDE 0207 part 21
4. Outer sheath
Rubber compound
5GM3 refer to
DIN VDE 0207 part 21,
low abrasion and notch
resistant, with anti-torsion
braid integrated in the sheath
Colour: black
Marking
RHEYCORD NSHTOEU-J
Number of cores - cross-section
0.6/1 kV - NEXANS <VDE>
year
Core Identification
DIN VDE 0293 part 308/
HD 308 S2
4 cores:
green/yellow - brown -
black - grey
5 cores:
green/yellow - blue - brown -
black - grey
≥ 5 cores:
black with white printed numbers -
green/yellow (in the outer layer)
Standards
DIN VDE 0250 part 814
Mechanical properties
| Tensile stress of the conductor |
static |
15 N/mm2 |
|
dynamic |
30 N/mm2 |
| Bending radii |
according to DIN VDE 298, |
|
| Tests |
alternating/reversed and roller bending test, |
|
|
torsional resistance test |
|
| Reeling speed |
up to 120 m/min |
|
Chemical properties
Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.
Electrical and Thermal properties
| Nominal voltage |
Uo/U |
0.6/1 kV |
| Maximum operating voltage in AC systems |
Um |
1.2 kV |
| Maximum operating voltage in DC systems |
Vm |
1.8 kV |
| Test voltage: |
|
| - Power |
2.5 kV in AC |
|
| - Control |
2.0 kV in AC |
|
| Current rating (A) |
according to DIN VDE 0298 part 4, |
|
|
see electrical characteristics page 3.2 B |
|
| Max. temperature at the conductor : |
|
| - in service |
+ 90 °C |
|
| - under short-circuit conditions |
+ 200 °C |
|
| Max. surface temperature : |
|
| - fixed installation |
- 45 °C up to + 80 °C |
|
| - mobile operation |
- 35 °C up to + 80 °C |
|
|
Number of cores and
nominal cross-section |
Outer diameter |
Weight
approx. |
|
(mm2) |
Min.
(mm) |
Max.
(mm) |
(kg/km) |
| CONTROL |
3 x 1.5* |
12 |
14 |
210 |
4 x 1.5* |
13 |
15 |
250 |
5 x 1.5 * |
14 |
16 |
285 |
7 x 1.5 * |
18 |
20 |
405 |
12 x 1.5* |
20 |
22 |
570 |
18 x 1.5* |
24 |
26 |
790 |
24 x 1.5* |
27 |
29 |
1,000 |
30 x 1.5* |
30 |
32 |
1,215 |
42 x 1.5* |
36 |
39 |
1,700 |
4 x 2.5* |
15 |
17 |
320 |
5 x 2.5* |
17 |
19 |
430 |
7 x 2.5* |
20 |
22 |
525 |
12 x 2.5* |
23 |
25 |
750 |
18 x 2.5 |
27 |
29 |
1,060 |
24 x 2.5* |
32 |
34 |
1,455 |
30 x 2.5 |
33 |
35 |
1,575 |
50 x 2.5* |
45 |
47 |
2,855 |
| POWER |
4 x 4* |
18 |
20 |
465 |
4 x 6* |
20 |
22 |
585 |
4 x 10* |
24 |
26 |
900 |
4 x 16* |
27 |
29 |
1,235 |
4 x 25* |
33 |
35 |
1,830 |
4 x 35* |
36 |
38 |
2,360 |
4 x 50* |
42 |
44 |
3,210 |
4 x 70* |
47 |
49 |
4,345 |
4 x 95* |
54 |
56 |
5,565 |
4 x 120* |
61 |
63 |
6,895 |
5 x 4* |
19 |
21 |
550 |
5 x 6* |
22 |
24 |
730 |
| BUS |
6 x (2 x 1.5) C* |
28 |
31 |
980 |
| COMPOSITE |
19 x 2.5 + 5 x 1.5 (CE)* |
31 |
33 |
1,450 |
25 x 2.5 + 5 x 1.5 (CE)* |
35 |
37 |
1,850 |
Options
• Further numbers of cores and cross-section upon request
• Integrated BUS system cable
• Integrated Optical Fiber Elements
• Special cold resistant compound
|