CSE Cable
CSE Cables - Supplier of industrial cable
Reeling Cables
H07VVH6-F
VCVH6-F
Rheyflat-N NGFLGOEU-J
Rheyflat-N (N)GFLCGOEU-J
LSHF
RHEYFESTOON (N)3GRD5G
RHEYFESTOON (C) (N)3GRDGC5G
RHEYCORD-OFE M
BUFLEX DGR
RHEYCORD NSHTOEU-J
RHEYCORD (RTS) (N)SHTOEU-J
RHEYCORD-PUR R
BUFLEX SC
BUFLEX SEM
BUFLEX SEM OFE
RHEYFIRM (RTS) (N)TSCGEWTOEUS
RHEYFIRM (RTS) (N)TSCGEWTOEUS OFE
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
RHEYCORD-OFE R
RHEYCORD-OFE SR
Special Cables
BOITALYON R
RHEYFLEX-PN
RHEYCORD(BS) YSLZ3SOE-J
RHEYFIRM(SI) NTMCGCWOEUS
Further Information
Cable Conductors
Cable Compounds
Cable Strength Member
Anti Torsion Braid
Bending Radius
Letter Codes
Units of Measurement
Voltage Definition
Current Carrying
BUS System
Optical Fibre
Mechanical Testing for Handling Cables
 

BOITALYON®R BOITALYON®R

PVC Pendant Overhead Crane Cables

 

Applications

Special cable with lateral suspension strands used to remote control overhead cranes from pushbutton boxes. It can be used for nstallations
where the hanging length of cable does not exceed 50 m.

Design

1. Conductor
Flexible, plain copper class 5
IEC 60228

2. Insulation
XLPE

Boitalyon Design3. Lateral suspension members
Sheathed stranded steel wires

4. Twin “figure 8” outer sheath PVC
Colour: black

Marking

BOITALYON - 300/500 V
Number of cores - cross-section NEXANS - year - week

Cores Identification

White printed numbers with or without earth core (green-yellow)

Standards

Nexans specification

Mechanical Properties

Max. tensile load of the two steel supports  1,000 N 
Bending radii  10 x D (cable diameter) 
Tests  alternating/reversed bending test, torsional resistance test 


Chemical properties

Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.

Optical and Thermal properties

Nominal voltage  Uo/U  300/500 V 
Maximum operating voltage in AC systems  Um  500 V 
Test voltage  2.5 kV in AC   
Current rating (A)  see electrical characteristics page 3.2 B   
Max. temperature at the conductor:   
- in service + 90 °C   
- in short circuit + 250 °C   
Max. surface temperature:   
- mobile operation - 25 °C up to + 60 °C   

Boitalyon R

Number of cores and nominal cross-section 
Outer dimensions approx. 
Weight approx. 
(mm2
(mm) 
(kg/km) 
5 x 1.5* 
20.0 x 9.5 
210
8 x 1.5* 
24.0 x 12.5 
300
12 x 1.5* 
24.0 x 12.5 
350
12 G 1.5* 
24.0 x 12.5 
350
16 x 1.5* 
25.5 x 14.5 
440
20 x 1.5* 
27.0 x 15.5 
520
20 G 1.5* 
27.0 x 15.5 
520
30 x 1.5* 
30.0 x 19.0 
700

 

CSE Cables : Unit 16, Wessex Road, Bourne End, Bucks, SL8 5DT
Tel : 01628 850024; Fax : 01628 648068; Email :
CSE Cable