RHEYCORD®(BS) YSLZ3SOE-J Special control cable for basket
spreader applications, e.g. in
Ship to Shore (STS) cranes,
Rail Mounted Gantry cranes
(RMG) and Rubber Tired Gantry
cranes (RTG).
1. Conductor
Extra flexible, plain copper,
according to IEC 60228
DIN VDE 0295 class 6
2. Insulation
PVC compound TI4 refer to
DIN VDE 0281 part 1
3. Core assembling
Bundle stranding with/without
EMC screen and heavy weight
chain unleaded elements
4. Outer sheath
Elastomere compound,
heavy duty abrasion
and notch-resistant
Colour: black
RHEYCORD(BS) YSLZ3SOE
Number of cores - cross-section
450/750 V - NEXANS - year
DIN VDE 0293 part 308
black with white printed numbers
+ green/yellow cores.
Nexans specification
| Tensile stress of the conductor | static | 15 N/mm2 |
| dynamic | 30 N/mm2 | |
| Bending radii | according to DIN VDE 298, | |
| see construction characteristics page 3.1 E | ||
| Tests | alternating/reversed bending test, torsional resistance test | |
| Travelling speed | up to 160 m/min | |
Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.
| Nominal voltage | Uo/U | 450/750 V |
| Maximum operating voltage in AC systems | Um | 825 V |
| Maximum operating voltage in DC systems | Vm | 1,238 V |
| Test voltage | 2.5 kV in AC | |
| Current rating (A) | according to DIN VDE 0298 part 4, | |
| see electrical characteristics page 3.2 B | ||
| Max. temperature at the conductor: | ||
| - in service | + 70°C | |
| - under short-circuit conditions | + 150°C | |
| Max. surface temperature: | ||
| - fixed installation | - 35 °C up to + 70°C | |