RHEYFIRM®(RS)-FLAT (N)TSFLCGCWOEUS
Reeling Flat Cables with/without Integrated Optical Fibers 3.6/6 (7.2) kV 6/10 (12) kV 8.7/15 (18) kV
Applications
Flexible flat reeling cable for
data transmission and for
energy supply. Especially for
high and extreme mechanical
stress used in Ship to Shore
Cranes (STS), Rail Mounted
Gantry Cranes (RMG) and other
heavy mobile equipments.
Design
1. Conductor
Flexible, plain copper, “FSC”
better than IEC 60228 class 5
2. Insulation
Inner semi-conductive layer
New special insulation
compound “RHEYCLEAN”
based on EPDM, better than
DIN VDE 207 part 20.
Outer semi-conductive layer,
“RHEYSTRIP”, easy strip
design
3. Protective earth conductor
Individually concentric mixed
braid of tinned copper wires
and high-tech polyamid yarn
4. Optical Fiber
Fiber diameter
9/125 μm
50/125 μm
62.5/125 μm
5. Outer sheath
Special rubber compound
Colour: red
Marking
RHEYFIRM(RS)-FLAT
(N)TSFLCGCWOEUS
Number of cores - cross-section
Voltage - NEXANS - year
Core Identification
Parallel arranged
Standards
In line with
DIN VDE 0250 part 813
DIN VDE 0295
DIN VDE 0298
DIN VDE 0472
pr EN 50363
Mechanical properties
| Tensile stress of the conductor |
20 N/mm2 |
| Bending radii |
according to DIN VDE 298, |
| Tests |
Bending test |
| Reeling speed |
on request |
Chemical properties
Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.
Electrical, Optical and Thermal properties
| Nominal voltage |
Uo/U |
3.6/6 kV to 8.7/15 kV |
| Maximum operation voltage in AC systems |
Um |
1.2 x U |
| Maximum operation voltage in DC systems |
Vm |
1.8 x U |
| Test voltage (according to DIN VDE 0250 part 813) |
11 kV to 24 kV in AC |
|
|
27.5 kV to 60 kV in DC |
|
| Current rating (A) |
according to DIN VDE 0298 part 4, |
|
|
see electrical characteristics page 3.2 B |
|
| Max. temperature at the conductor: |
|
| - in service |
+ 90 °C |
|
| - under short-circuit conditions |
+ 250 °C |
|
| Max. surface temperature: |
|
| - fixed installation |
- 50 °C up to + 80 °C |
|
| - mobile operation |
- 35 °C up to + 80 °C |
|
Number of cores and
nominal cross-section |
Outer dimensions |
Weight
approx. |
Tensile
strength |
(mm2) |
Min.
(mm) |
Max.
(mm) |
(kg/km) |
(N) |
3.6/6 kV |
4 x 35 |
24 x 77 |
25 x 79 |
3,600 |
2,800 |
3 x 35/35 + OFE |
24 x 77 |
25 x 79 |
3,600 |
2,100 |
4 x 50 |
26 x 83 |
27 x 85 |
4,400 |
4,000 |
| 3 x 50/50 + OFE |
26 x 83 |
27 x 85 |
4,400 |
3,000 |
|
|
6/10 kV |
|
|
4 x 35 |
26 x 78 |
27 x 80 |
3,900 |
2,800 |
3 x 35/35 + OFE |
26 x 78 |
27 x 80 |
3,900 |
2,100 |
8.7/15 kV |
4 x 35 |
27 x 79 |
28 x 81 |
4,200 |
2,800 |
3 x 35/35 + OFE |
27 x 79 |
28 x 81 |
4,200 |
2,100 |
Options
• Voltage level 0.6/1 (1.2) kV on request
• Other sheath qualities and colours
• Including signal cores, telecommunication cores
• Pre-assembled with sealing ends upon request
|