CSE Cable
CSE Cables - Supplier of industrial cable
Reeling Cables
H07VVH6-F
VCVH6-F
Rheyflat-N NGFLGOEU-J
Rheyflat-N (N)GFLCGOEU-J
LSHF
RHEYFESTOON (N)3GRD5G
RHEYFESTOON (C) (N)3GRDGC5G
RHEYCORD-OFE M
BUFLEX DGR
RHEYCORD NSHTOEU-J
RHEYCORD (RTS) (N)SHTOEU-J
RHEYCORD-PUR R
BUFLEX SC
BUFLEX SEM
BUFLEX SEM OFE
RHEYFIRM (RTS) (N)TSCGEWTOEUS
RHEYFIRM (RTS) (N)TSCGEWTOEUS OFE
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
RHEYCORD-OFE R
RHEYCORD-OFE SR
Special Cables
BOITALYON R
RHEYFLEX-PN
RHEYCORD(BS) YSLZ3SOE-J
RHEYFIRM(SI) NTMCGCWOEUS
Further Information
Cable Conductors
Cable Compounds
Cable Strength Member
Anti Torsion Braid
Bending Radius
Letter Codes
Units of Measurement
Voltage Definition
Current Carrying
BUS System
Optical Fibre
Mechanical Testing for Handling Cables
 

RHEYFIRM®(RS)-FLAT (N)TSFLCGCWOEUS

RHEYFIRM®(RS)-FLAT (N)TSFLCGCWOEUSReeling Flat Cables with/without Integrated Optical Fibers 3.6/6 (7.2) kV 6/10 (12) kV 8.7/15 (18) kV

 

Applications

Flexible flat reeling cable for data transmission and for energy supply. Especially for high and extreme mechanical stress used in Ship to Shore Cranes (STS), Rail Mounted Gantry Cranes (RMG) and other
heavy mobile equipments.

Design

1. Conductor
Flexible, plain copper, “FSC” better than IEC 60228 class 5

2. Insulation
Inner semi-conductive layer
New special insulation compound “RHEYCLEAN” based on EPDM, better than DIN VDE 207 part 20.
Rheyfirm Flat N TSFLCGCWOEUSOuter semi-conductive layer,
“RHEYSTRIP”, easy strip design

3. Protective earth conductor
Individually concentric mixed braid of tinned copper wires and high-tech polyamid yarn

4. Optical Fiber
Fiber diameter
9/125 μm
50/125 μm
62.5/125 μm

5. Outer sheath
Special rubber compound
Colour: red

Marking

RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
Number of cores - cross-section Voltage - NEXANS - year

Core Identification

Parallel arranged

Standards

In line with
DIN VDE 0250 part 813
DIN VDE 0295
DIN VDE 0298
DIN VDE 0472
pr EN 50363

Mechanical properties

Tensile stress of the conductor  20 N/mm2 
Bending radii  according to DIN VDE 298, 
Tests  Bending test 
Reeling speed  on request 


Chemical properties

Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1.

Electrical, Optical and Thermal properties

Nominal voltage  Uo/U  3.6/6 kV to 8.7/15 kV 
Maximum operation voltage in AC systems  Um  1.2 x U 
Maximum operation voltage in DC systems  Vm  1.8 x U 
Test voltage (according to DIN VDE 0250 part 813)  11 kV to 24 kV in AC   
27.5 kV to 60 kV in DC   
Current rating (A)  according to DIN VDE 0298 part 4,   
see electrical characteristics page 3.2 B   
Max. temperature at the conductor:   
- in service + 90 °C   
- under short-circuit conditions + 250 °C   
Max. surface temperature:   
- fixed installation - 50 °C up to + 80 °C   
- mobile operation - 35 °C up to + 80 °C   

 

Number of cores and
nominal cross-section
Outer dimensions
Weight
approx.
Tensile
strength
(mm2)
Min.
(mm)
Max.
(mm)
(kg/km)
(N)
3.6/6 kV
4 x 35
24 x 77
25 x 79
3,600
2,800 
3 x 35/35 + OFE
24 x 77
25 x 79
3,600
2,100
4 x 50
26 x 83
27 x 85  
4,400
4,000
3 x 50/50 + OFE 
26 x 83 
27 x 85
4,400 
3,000
6/10 kV 
4 x 35
26 x 78
27 x 80
3,900
2,800 
3 x 35/35 + OFE 
26 x 78 
27 x 80 
3,900 
2,100
8.7/15 kV
4 x 35  
27 x 79
28 x 81
4,200
2,800
3 x 35/35 + OFE
27 x 79 
28 x 81 
4,200 
2,100 

Options
• Voltage level 0.6/1 (1.2) kV on request
• Other sheath qualities and colours
• Including signal cores, telecommunication cores
• Pre-assembled with sealing ends upon request

 

 

CSE Cables : Unit 16, Wessex Road, Bourne End, Bucks, SL8 5DT
Tel : 01628 850024; Fax : 01628 648068; Email :
CSE Cable