CSE Cable
CSE Cables - Supplier of industrial cable
Reeling Cables
H07VVH6-F
VCVH6-F
Rheyflat-N NGFLGOEU-J
Rheyflat-N (N)GFLCGOEU-J
LSHF
RHEYFESTOON (N)3GRD5G
RHEYFESTOON (C) (N)3GRDGC5G
RHEYCORD-OFE M
BUFLEX DGR
RHEYCORD NSHTOEU-J
RHEYCORD (RTS) (N)SHTOEU-J
RHEYCORD-PUR R
BUFLEX SC
BUFLEX SEM
BUFLEX SEM OFE
RHEYFIRM (RTS) (N)TSCGEWTOEUS
RHEYFIRM (RTS) (N)TSCGEWTOEUS OFE
RHEYFIRM(RS)-FLAT (N)TSFLCGCWOEUS
RHEYCORD-OFE R
RHEYCORD-OFE SR
Special Cables
BOITALYON R
RHEYFLEX-PN
RHEYCORD(BS) YSLZ3SOE-J
RHEYFIRM(SI) NTMCGCWOEUS
Further Information
Cable Conductors
Cable Compounds
Cable Strength Member
Anti Torsion Braid
Bending Radius
Letter Codes
Units of Measurement
Voltage Definition
Current Carrying
BUS System
Optical Fibre
Mechanical Testing for Handling Cables
 

Rheyfirm SIRHEYFIRM®(SI) NTMCGCWOEUS

Flexible Single-Core Connection Cables 6/10 kV 12/20 kV

 

Applications

Flexible high voltage cable 12/20 kV used normally in short lengths, e.g. between short-circuit breaker and mobile transformer

Design

1. Conductor
Flexible, tinned copper, IEC 60228 class 5

2. Insulation
Inner semi-conductive layer New special insulation compound “RHEYCLEAN” based on EPDM, better than DIN VDE 207 part 20.
Outer semi-conductive layer,“RHEYSTRIP”, easy strip design

Rheyfirm SI Ntmcgcwoeus3. Screen
Close spinning of tinned copper wires/ tinned stranded wires

4. Outer sheath
Rubber compound 5GM5 refer to DIN VDE 0207 part 21, heavy duty abrasion and notch-resistant
Colour: red

Marking

RHEYFIRM(SI) NTMCGCWOEUS
1 x cross-section - Voltage NEXANS <VDE> - year

Core Identification

Single core design

Standards

DIN VDE 0250 part 813
DIN VDE 0298
DIN VDE 0298 part 4

Mechanical properties

Tensile stress of the conductor  static  15 N/mm2 
dynamic  30 N/mm2 
Bending radii  according to DIN VDE 298, 
Tests  alternating/reversed bending test   

Chemical Properties

Oil resistant.
For indoor and outdoor applications. Moisture, UV and ozone resistance.
Flame-retardant according to IEC 60 332 part 1

Electrical and Thermal properties

Nominal voltage  Uo/U  6/10 kV to 12/20 kV 
Test voltage (according to DIN VDE 0250 part 813)  17 to 29 kV in AC   
Current rating (A)  according to DIN VDE 0298 part 4,   
see electrical characteristics page 3.2 B   
Max. temperature at the conductor:   
- in service + 90 °C   
- under short-circuit conditions + 200 °C   
Max. surface temperature:   
- fixed installation - 35 °C up to + 80 °C   


RHEYFIRM®(SI) NTMCGCWOEUS

Number of cores and
nominal cross-section
Outer diameter
Weight
approx.
(mm2)
Min.
(mm)
Max.
(mm)
(kg/km)
6/10 kV
1 x 16/16 
20
23
690
1 x 25/16 
21
24
800
1 x 35/16* 
22
25
920
1 x 50/16* 
24
27
1,100
1 x 70/16* 
26
29
1,360
1 x 95/16* 
28
31
1,610
1 x 120/16* 
29
32
1,870
1 x 150/25 
32
35
2,320
1 x 185/25 
34
37
2,650
1 x 240/25 
38
41
3,320
12/20 kV
1 x 16/16 
24
27
870
1 x 25/16* 
26
29
1,030
1 x 35/16* 
27
30
1,150
1 x 50/16* 
29
32
1,340
1 x 70/16* 
30
33
1,580
1 x 95/16* 
33
36
1,920
1 x 120/16* 
35
38
2,190
1 x 150/25* 
36
39
2,610
1 x 185/25* 
39
42
3,040
1 x 240/25* 
42
45
3,660

Options

Pre-assembled with sealing ends upon request
• Other voltages on request