Loading

CSE BT2003 Coax Telecom CableTelecom Coax Cable - CSE BT2003 PVC

The CSE BT 2003 PVC CSE-235-2 is suitable for communication and signal control systems.

Cable Construction

Inner Conductor Bare Copper 0.61mm
Insulation Insulation Thickness 1.545mm
  Solid PE 3.7mm
  Colour Natural
Sheild 1 (braiding) Bare Copper 0.15 x 24 x 5
  Coverage >93%
Shield 2 (braiding) Bare Copper 0.15 x 24 x 5
  Coverage >92%
Jacket Jacket thickness 0.85mm
  PVC 6.7mm
  Colour White
Marking Black Ink  

Electrical Characteristics

Max.Conductor DC Resistance at 20℃(Ω/Km) <63.7
Min.Insulation DC Resistance at 20℃(MΩ*Km) 20000
Rated Temperature (℃) -20 to 70
Rated Voltage (V) 30
Velocity ratio (%) 67.7%
Impedance (Ω) 75±3
Capacitance(pF/m) <70
Attenuation at 20℃ (-dB/100m)(±8%)  
5MHz 2.5
50MHz 9.0
200MHz 18.4
600MHz 32.4
1000MHz 41.8
FESXTR at 20℃  
0.01MHz >70
1.0MHz >120
17MHz >133
Strippability (Centre conductor from the dielectric 30mm) >20N
Strippability ( The sheath from the cable 30mm) 15N<F<20N

RoHS (2002/95/EC) Compliant - This product conforms to the above standard

Information in this data sheet supplied to users is based on general experience and is given in good faith, but because of the many particular factors which are outside our knowledge which affect the use of the products, no warranty is given nor is to be implied with respect to such information. Users should make their own enquiries to determine the stability of products for any particular use.